Balay
Start Circuit / User Interface Fault
Dryer powers on but will not start when Start button is pressed
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty Start/Pause button, Child lock function active, Door not detected as closed, Defective user interface PCB
How to Fix / Troubleshooting
Safety first: Disconnect mains power before removing the control panel.
Steps to check and fix:
- Check display indicators: Ensure the child lock is not active (usually indicated by a key symbol). Deactivate according to the user manual.
- Verify door closure: Confirm that the door is fully closed and that the door-closed symbol appears on the display if applicable.
- Test Start button: Remove the control panel and test the Start/Pause button switch with a multimeter. Replace the button or user interface board if the switch is defective.
- Inspect ribbon cables: Ensure the ribbon cable between the user interface and main PCB is firmly seated and undamaged.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements