E18
Beko Mains Supply / Frequency Detection Fault

Dryer shows E18; may be associated with low voltage or mains frequency detection on some electronic models.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unstable or low mains voltage, Incompatible inverter or generator supply, Faulty mains sensing circuit on PCB, Loose mains connections

How to Fix / Troubleshooting

Safety first: Always disconnect the dryer before inspecting electrical connections.

  • Check supply quality: Ensure the dryer is connected directly to a standard wall outlet, not via a long extension or low-quality inverter.
  • Test voltage: Use a multimeter (if competent) to verify that the mains voltage is within the range specified on the rating plate.
  • Inspect terminal block: Check the internal mains terminal block for loose screws or heat damage. Tighten and repair as needed.
  • Try a different outlet: Plug the dryer into another known-good circuit to rule out house wiring issues.
  • If E18 continues with good supply: The mains sensing circuitry on the PCB may be defective and require board replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board
Check Price on Amazon