Belling Early Cycle Termination on Sensor-Dry

Dryer stops shortly after starting; clothes remain very wet and cool, no error code shown.

Advertisements

Possible Causes

Dirty or insulated moisture sensor bars, Poor drum grounding, Faulty moisture sensor wiring, Incorrect program selection for load type

How to Fix / Troubleshooting

Safety first: Unplug the dryer before cleaning sensor contacts.

Sensor cleaning:

  • Locate the moisture sensor bars inside the drum near the door.
  • Clean them thoroughly with a mild abrasive pad to remove any film from fabric softeners.

Grounding and wiring:

  • Check the earth strap from the drum to the chassis for secure connection.
  • Inspect sensor wiring behind the front panel for damage.

Usage:

  • For very small loads or single items, use a timed program instead of sensor-dry, as the sensors may not detect moisture reliably.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Moisture Sensor Bars
Check Price on Amazon