Belling No Power / Supply Fault

Dryer will not start at all; no lights or display, completely dead.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown mains fuse in plug, Faulty mains cable, Loose connection at terminal block, Failed main control PCB power supply

How to Fix / Troubleshooting

Safety first: Ensure the dryer is unplugged before opening any covers.

External checks:

  • Test the wall socket with another appliance.
  • Check and replace the fuse in the dryer plug if blown, using the correct rating.

Internal checks:

  • Remove the top cover and inspect the mains terminal block for loose wires or heat damage. Tighten screws and replace burnt parts.
  • Check the mains cable for visible damage; replace if necessary.

Control board: If power is present at the terminal block but the dryer remains dead, the main control PCB power supply is likely faulty and the board will need replacement by a qualified technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Mains Cable
Check Price on Amazon