E95
Electrolux Serial Communication Error / Control Board Internal Fault

Dryer displays E95 and is inoperative

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Internal failure of main control board, Severe power surge, Manufacturing defect

How to Fix / Troubleshooting

Safety first: Unplug the dryer.

This error generally indicates an internal failure of the main control board.

  • Power cycle: After 15 minutes without power, reconnect and test. If E95 reappears, the board is likely defective.

Replace the main control board with the correct Electrolux part. Programming may be required; this is best handled by an authorized technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon