E11
Dryer will not start a cycle; E11 displayed shortly after pressing Start
Door Lock / Door Switch Fault
E13
Dryer stops shortly after starting; E13 displayed (often on Electrolux condenser/heat pump dryers)
Condensate Pump / Water Level Fault
E24
Dryer does not heat properly; E24 displayed on control panel
NTC Temperature Sensor Fault (Exhaust or Drum Sensor)
E25
Dryer stops heating or shuts down; E25 displayed
Drum / Inlet Temperature Sensor Fault
E32
Dryer will not start or stops mid-cycle; E32 displayed
Moisture Sensor Circuit Fault
E33
Dryer ends cycle too quickly or will not start auto cycles; E33 displayed
Moisture Sensor Calibration / Short Circuit Fault
E51
Dryer will not start; E51 displayed; sometimes a click is heard but drum does not turn
Motor Relay or Motor Drive Fault
E52
Dryer drum turns erratically or stops; E52 displayed intermittently
Motor Tachometer / Speed Feedback Fault
E54
Dryer will not start or stops abruptly; E54 displayed
Motor Relay Stuck or Shorted
E61
Dryer runs but does not heat properly; E61 displayed (often on heat pump models)
Heating System Performance Fault
E62
Dryer overheats or shuts down quickly; E62 displayed
Overheating / High Temperature Fault
E63
Dryer does not heat; E63 displayed
Heater Circuit Open / Heater Relay Fault
E64
Dryer heats weakly or intermittently; E64 displayed
Partial Heater Failure / Heater Relay Performance Fault
E66
Dryer will not heat; E66 displayed
Thermal Limiter / Safety Thermostat Tripped
E68
Dryer will not start or behaves erratically; E68 displayed
Keypad / Button Stuck or Shorted
E71
Dryer will not heat or ends cycle quickly; E71 displayed
NTC Temperature Sensor Out of Range (High Resistance)
E72
Dryer temperature erratic; E72 displayed
NTC Temperature Sensor Out of Range (Low Resistance)
E73
Dryer will not start or heats incorrectly; E73 displayed
Secondary NTC Sensor Fault (e.g., Ambient or Condenser Sensor)
E75
Dryer displays E75 and may not heat correctly (common on some heat pump models)
Inlet / Outlet Temperature Sensor Correlation Fault
E82
Dryer control panel unresponsive or displays incorrect options; E82 displayed
User Interface / Control Board Communication Fault
E83
Dryer shows E83 and may not respond to commands
Configuration / Communication Error Between Boards
E91
Dryer displays E91 and does not start
Communication Error Between Main Control and User Interface
E92
Dryer shows E92 and may have incorrect or missing options on the display
Configuration Error / UI and Main Board Mismatch
E93
Dryer displays E93 and will not operate
Configuration Fault / Invalid Option Set
E94
Dryer shows E94 and may not start or may behave unpredictably
Program Memory / EEPROM Fault
E95
Dryer displays E95 and is inoperative
Serial Communication Error / Control Board Internal Fault
Symptom
Dryer control panel lights up but buttons do not respond or respond intermittently
User Interface / Touchpad Failure
Symptom
Dryer display and controls are dead; unit shows no signs of power
Power Supply / Main Control Failure
Symptom
Dryer door is hard to open or sticks closed after cycle
Door Seal / Latch Binding
Symptom
Dryer door will not stay closed or pops open during cycle
Door Latch / Strike Failure
Symptom
Dryer drum does not turn, but motor hums or clicks when Start is pressed
Drive Belt or Motor Start Failure
Symptom
Dryer drum light does not turn on when door is opened
Drum Light / Door Switch Circuit Fault
Symptom
Dryer leaks water onto the floor (condenser or heat pump models)
Condensate Drainage Problem
Symptom
Dryer makes loud squealing or screeching noise during operation
Worn Drum Support Components
Symptom
Dryer makes loud thumping or banging noise, especially with heavy loads
Drum Support / Out-of-Round Drum
Symptom
Dryer produces a burning smell during operation
Overheating or Foreign Object Contact
Symptom
Dryer runs but clothes come out wrinkled or very hot at end of cycle
Temperature Control / Cool-Down Issue
Symptom
Dryer runs but does not heat at all (no error code displayed)
No-Heat Condition Without Error
Symptom
Dryer stops mid-cycle and will not restart until it cools down
Overheating / Motor or Thermostat Trip
Symptom
Dryer takes too long to dry clothes; clothes are warm but still damp at end of cycle
Restricted Airflow / Poor Drying Performance
Symptom
Dryer vibrates excessively or walks across the floor during operation
Vibration / Installation Issue
Symptom
Dryer will not start at all; no drum movement, but lights may be on
Start Circuit / Door Interlock Issue
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E11 |
Dryer will not start a cycle; E11 displayed shortly after pressing Start
|
Door Lock / Door Switch Fault | View Details |
| E13 |
Dryer stops shortly after starting; E13 displayed (often on Electrolux condenser/heat pump dryers)
|
Condensate Pump / Water Level Fault | View Details |
| E24 |
Dryer does not heat properly; E24 displayed on control panel
|
NTC Temperature Sensor Fault (Exhaust or Drum Sensor) | View Details |
| E25 |
Dryer stops heating or shuts down; E25 displayed
|
Drum / Inlet Temperature Sensor Fault | View Details |
| E32 |
Dryer will not start or stops mid-cycle; E32 displayed
|
Moisture Sensor Circuit Fault | View Details |
| E33 |
Dryer ends cycle too quickly or will not start auto cycles; E33 displayed
|
Moisture Sensor Calibration / Short Circuit Fault | View Details |
| E51 |
Dryer will not start; E51 displayed; sometimes a click is heard but drum does not turn
|
Motor Relay or Motor Drive Fault | View Details |
| E52 |
Dryer drum turns erratically or stops; E52 displayed intermittently
|
Motor Tachometer / Speed Feedback Fault | View Details |
| E54 |
Dryer will not start or stops abruptly; E54 displayed
|
Motor Relay Stuck or Shorted | View Details |
| E61 |
Dryer runs but does not heat properly; E61 displayed (often on heat pump models)
|
Heating System Performance Fault | View Details |
| E62 |
Dryer overheats or shuts down quickly; E62 displayed
|
Overheating / High Temperature Fault | View Details |
| E63 |
Dryer does not heat; E63 displayed
|
Heater Circuit Open / Heater Relay Fault | View Details |
| E64 |
Dryer heats weakly or intermittently; E64 displayed
|
Partial Heater Failure / Heater Relay Performance Fault | View Details |
| E66 |
Dryer will not heat; E66 displayed
|
Thermal Limiter / Safety Thermostat Tripped | View Details |
| E68 |
Dryer will not start or behaves erratically; E68 displayed
|
Keypad / Button Stuck or Shorted | View Details |
| E71 |
Dryer will not heat or ends cycle quickly; E71 displayed
|
NTC Temperature Sensor Out of Range (High Resistance) | View Details |
| E72 |
Dryer temperature erratic; E72 displayed
|
NTC Temperature Sensor Out of Range (Low Resistance) | View Details |
| E73 |
Dryer will not start or heats incorrectly; E73 displayed
|
Secondary NTC Sensor Fault (e.g., Ambient or Condenser Sensor) | View Details |
| E75 |
Dryer displays E75 and may not heat correctly (common on some heat pump models)
|
Inlet / Outlet Temperature Sensor Correlation Fault | View Details |
| E82 |
Dryer control panel unresponsive or displays incorrect options; E82 displayed
|
User Interface / Control Board Communication Fault | View Details |
| E83 |
Dryer shows E83 and may not respond to commands
|
Configuration / Communication Error Between Boards | View Details |
| E91 |
Dryer displays E91 and does not start
|
Communication Error Between Main Control and User Interface | View Details |
| E92 |
Dryer shows E92 and may have incorrect or missing options on the display
|
Configuration Error / UI and Main Board Mismatch | View Details |
| E93 |
Dryer displays E93 and will not operate
|
Configuration Fault / Invalid Option Set | View Details |
| E94 |
Dryer shows E94 and may not start or may behave unpredictably
|
Program Memory / EEPROM Fault | View Details |
| E95 |
Dryer displays E95 and is inoperative
|
Serial Communication Error / Control Board Internal Fault | View Details |
| – |
Dryer control panel lights up but buttons do not respond or respond intermittently
|
User Interface / Touchpad Failure | View Details |
| – |
Dryer display and controls are dead; unit shows no signs of power
|
Power Supply / Main Control Failure | View Details |
| – |
Dryer door is hard to open or sticks closed after cycle
|
Door Seal / Latch Binding | View Details |
| – |
Dryer door will not stay closed or pops open during cycle
|
Door Latch / Strike Failure | View Details |
| – |
Dryer drum does not turn, but motor hums or clicks when Start is pressed
|
Drive Belt or Motor Start Failure | View Details |
| – |
Dryer drum light does not turn on when door is opened
|
Drum Light / Door Switch Circuit Fault | View Details |
| – |
Dryer leaks water onto the floor (condenser or heat pump models)
|
Condensate Drainage Problem | View Details |
| – |
Dryer makes loud squealing or screeching noise during operation
|
Worn Drum Support Components | View Details |
| – |
Dryer makes loud thumping or banging noise, especially with heavy loads
|
Drum Support / Out-of-Round Drum | View Details |
| – |
Dryer produces a burning smell during operation
|
Overheating or Foreign Object Contact | View Details |
| – |
Dryer runs but clothes come out wrinkled or very hot at end of cycle
|
Temperature Control / Cool-Down Issue | View Details |
| – |
Dryer runs but does not heat at all (no error code displayed)
|
No-Heat Condition Without Error | View Details |
| – |
Dryer stops mid-cycle and will not restart until it cools down
|
Overheating / Motor or Thermostat Trip | View Details |
| – |
Dryer takes too long to dry clothes; clothes are warm but still damp at end of cycle
|
Restricted Airflow / Poor Drying Performance | View Details |
| – |
Dryer vibrates excessively or walks across the floor during operation
|
Vibration / Installation Issue | View Details |
| – |
Dryer will not start at all; no drum movement, but lights may be on
|
Start Circuit / Door Interlock Issue | View Details |