E4
Gorenje Heating Circuit Fault (Heater or Heat Pump Module)

Dryer does not heat properly; display shows E4.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed heating element (for vented/condenser models), Faulty heat pump compressor module (for heat pump models), Burned heater relay on control board, Broken wiring in heater circuit

How to Fix / Troubleshooting

Safety first: Disconnect power. Heating components carry mains voltage and can cause electric shock.

  • Confirm symptom: Run a timed program and check if the drum turns but air remains cold after 5–10 minutes.
  • Access heater: On many Gorenje vented/condenser dryers, the heater is behind the rear panel. Remove screws and carefully pull off the panel.
  • Test heating element: Disconnect heater terminals and measure resistance. A typical element reads 20–60 Ω. If open (infinite resistance), replace the heater assembly.
  • Inspect wiring and connectors: Look for burned spade connectors or melted insulation at the heater and thermostats. Repair or replace as needed.
  • Heat pump models: If your Gorenje dryer is a heat pump type, listen for compressor operation and fan noise. If the compressor never starts, the heat pump module or inverter board may be faulty and should be checked by a qualified technician.
  • Control board: If heater and wiring are good, the heater relay or control PCB may be defective. Replacement typically requires professional service.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heater Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements