E1
Dryer will not start; display shows E1 shortly after pressing Start.
Door Lock / Door Switch Fault
E10
Dryer displays E10 and may stop or fail to start; often related to heat pump models.
Heat Pump System Fault (Compressor / Refrigerant Circuit)
E11
Dryer shows E11; may be associated with water tank or condensate handling issues.
Condensate Pump / Water Level Sensor Fault
E12
Dryer displays E12; often related to water tank full indication even when empty.
Water Tank Full Sensor / Switch Fault
E13
Dryer shows E13 and may stop; often associated with internal leakage or overflow.
Internal Water Leak / Overflow Detection
E14
Dryer displays E14; may be related to sensor drying programs not working correctly.
Drum Temperature Sensor (Secondary NTC) Fault
E15
Dryer shows E15; may not start or may stop with a beeping alarm.
Door Locking System Advanced Fault
E16
Dryer displays E16; often associated with power supply or internal voltage issues.
Power Supply / Voltage Fault
E17
Dryer shows E17; may be related to communication between modules (e.g., main PCB and inverter).
Internal Communication Error
E18
Dryer displays E18; may be associated with sensor calibration or configuration issues.
Configuration / Calibration Error
E2
Dryer stops shortly after start or will not start; display shows E2.
NTC Temperature Sensor Fault (Inlet or Drum Sensor)
E3
Dryer stops mid-cycle or will not start; display shows E3.
Exhaust / Airflow Sensor or Overheating Fault
E4
Dryer does not heat properly; display shows E4.
Heating Circuit Fault (Heater or Heat Pump Module)
E5
Dryer stops and displays E5; may occur shortly after starting a cycle.
Moisture Sensor / Humidity Detection Fault
E6
Dryer displays E6 and may not start or may stop unexpectedly.
Motor / Drive Circuit Fault
E7
Dryer shows E7; may be accompanied by unusual temperature behavior or immediate shutdown.
Overtemperature / Safety Thermostat Trip
E8
Dryer displays E8; cycle may not start or may stop with poor drying performance.
Fan / Blower Motor Fault
E9
Dryer shows E9 and may not respond to button presses or behaves erratically.
Control Panel / User Interface Communication Fault
Symptom
Dryer display and buttons work, but the drum light and internal functions flicker or reset intermittently.
Intermittent Power / Loose Connection
Symptom
Dryer display is dim, flickering, or partially unreadable.
Display Module / Backlight Fault
Symptom
Dryer display shows very short remaining time but clothes are still wet at the end of the program.
Moisture Sensing / Auto-Dry Miscalibration
Symptom
Dryer display works but some buttons do not respond or respond intermittently.
User Interface Button / Touch Control Fault
Symptom
Dryer door opens during operation or does not stay closed securely.
Door Latch / Hinge Wear
Symptom
Dryer door will not open at the end of the cycle; door appears locked.
Door Lock Stuck / Mechanical Jam
Symptom
Dryer drum does not turn, but you can hear a humming sound when you press Start.
Drive Belt or Motor Start Capacitor Failure
Symptom
Dryer drum light stays on even when the door is closed, or never comes on at all.
Door Switch or Drum Light Circuit Fault
Symptom
Dryer emits a burning smell during operation.
Overheating or Foreign Object Contact with Heater
Symptom
Dryer interior or laundry has a musty or unpleasant odor after drying.
Bacterial / Mold Growth in Moist Areas
Symptom
Dryer is very noisy during operation; grinding, squealing, or rumbling sounds from the drum area.
Drum Support / Bearing Wear
Symptom
Dryer leaks water onto the floor during or after a cycle.
Condensate Drainage / Tank System Leak
Symptom
Dryer makes a loud banging or thumping noise, especially with small loads.
Drum Imbalance / Worn Suspension
Symptom
Dryer powers on but will not start a cycle when Start is pressed.
Start Circuit / Safety Interlock Issue
Symptom
Dryer produces excessive lint around the appliance or in the room.
Lint Filtration / Sealing Problem
Symptom
Dryer runs but does not heat; clothes remain cold and wet at the end of the cycle.
Heating Element or Heat Pump Failure
Symptom
Dryer runs for a few minutes then shuts off completely without any error on the display.
Motor Overload / Thermal Protection Trip
Symptom
Dryer stops mid-cycle and the drum light remains on; can be restarted but stops again.
Overheating / Thermal Cut-Out Cycling
Symptom
Dryer takes too long to dry; cycles run much longer than usual and clothes are still damp.
Restricted Airflow / Reduced Heating Efficiency
Symptom
Dryer vibrates excessively and moves across the floor during operation.
Installation / Support Imbalance
Symptom
Dryer will not start at all; no lights or display when plugged in.
No Power / Main Supply Fault
Symptom
Water tank fills very quickly or overflows during a single cycle.
Condensation Inefficiency / Airflow Restriction
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E1 |
Dryer will not start; display shows E1 shortly after pressing Start.
|
Door Lock / Door Switch Fault | View Details |
| E10 |
Dryer displays E10 and may stop or fail to start; often related to heat pump models.
|
Heat Pump System Fault (Compressor / Refrigerant Circuit) | View Details |
| E11 |
Dryer shows E11; may be associated with water tank or condensate handling issues.
|
Condensate Pump / Water Level Sensor Fault | View Details |
| E12 |
Dryer displays E12; often related to water tank full indication even when empty.
|
Water Tank Full Sensor / Switch Fault | View Details |
| E13 |
Dryer shows E13 and may stop; often associated with internal leakage or overflow.
|
Internal Water Leak / Overflow Detection | View Details |
| E14 |
Dryer displays E14; may be related to sensor drying programs not working correctly.
|
Drum Temperature Sensor (Secondary NTC) Fault | View Details |
| E15 |
Dryer shows E15; may not start or may stop with a beeping alarm.
|
Door Locking System Advanced Fault | View Details |
| E16 |
Dryer displays E16; often associated with power supply or internal voltage issues.
|
Power Supply / Voltage Fault | View Details |
| E17 |
Dryer shows E17; may be related to communication between modules (e.g., main PCB and inverter).
|
Internal Communication Error | View Details |
| E18 |
Dryer displays E18; may be associated with sensor calibration or configuration issues.
|
Configuration / Calibration Error | View Details |
| E2 |
Dryer stops shortly after start or will not start; display shows E2.
|
NTC Temperature Sensor Fault (Inlet or Drum Sensor) | View Details |
| E3 |
Dryer stops mid-cycle or will not start; display shows E3.
|
Exhaust / Airflow Sensor or Overheating Fault | View Details |
| E4 |
Dryer does not heat properly; display shows E4.
|
Heating Circuit Fault (Heater or Heat Pump Module) | View Details |
| E5 |
Dryer stops and displays E5; may occur shortly after starting a cycle.
|
Moisture Sensor / Humidity Detection Fault | View Details |
| E6 |
Dryer displays E6 and may not start or may stop unexpectedly.
|
Motor / Drive Circuit Fault | View Details |
| E7 |
Dryer shows E7; may be accompanied by unusual temperature behavior or immediate shutdown.
|
Overtemperature / Safety Thermostat Trip | View Details |
| E8 |
Dryer displays E8; cycle may not start or may stop with poor drying performance.
|
Fan / Blower Motor Fault | View Details |
| E9 |
Dryer shows E9 and may not respond to button presses or behaves erratically.
|
Control Panel / User Interface Communication Fault | View Details |
| – |
Dryer display and buttons work, but the drum light and internal functions flicker or reset intermittently.
|
Intermittent Power / Loose Connection | View Details |
| – |
Dryer display is dim, flickering, or partially unreadable.
|
Display Module / Backlight Fault | View Details |
| – |
Dryer display shows very short remaining time but clothes are still wet at the end of the program.
|
Moisture Sensing / Auto-Dry Miscalibration | View Details |
| – |
Dryer display works but some buttons do not respond or respond intermittently.
|
User Interface Button / Touch Control Fault | View Details |
| – |
Dryer door opens during operation or does not stay closed securely.
|
Door Latch / Hinge Wear | View Details |
| – |
Dryer door will not open at the end of the cycle; door appears locked.
|
Door Lock Stuck / Mechanical Jam | View Details |
| – |
Dryer drum does not turn, but you can hear a humming sound when you press Start.
|
Drive Belt or Motor Start Capacitor Failure | View Details |
| – |
Dryer drum light stays on even when the door is closed, or never comes on at all.
|
Door Switch or Drum Light Circuit Fault | View Details |
| – |
Dryer emits a burning smell during operation.
|
Overheating or Foreign Object Contact with Heater | View Details |
| – |
Dryer interior or laundry has a musty or unpleasant odor after drying.
|
Bacterial / Mold Growth in Moist Areas | View Details |
| – |
Dryer is very noisy during operation; grinding, squealing, or rumbling sounds from the drum area.
|
Drum Support / Bearing Wear | View Details |
| – |
Dryer leaks water onto the floor during or after a cycle.
|
Condensate Drainage / Tank System Leak | View Details |
| – |
Dryer makes a loud banging or thumping noise, especially with small loads.
|
Drum Imbalance / Worn Suspension | View Details |
| – |
Dryer powers on but will not start a cycle when Start is pressed.
|
Start Circuit / Safety Interlock Issue | View Details |
| – |
Dryer produces excessive lint around the appliance or in the room.
|
Lint Filtration / Sealing Problem | View Details |
| – |
Dryer runs but does not heat; clothes remain cold and wet at the end of the cycle.
|
Heating Element or Heat Pump Failure | View Details |
| – |
Dryer runs for a few minutes then shuts off completely without any error on the display.
|
Motor Overload / Thermal Protection Trip | View Details |
| – |
Dryer stops mid-cycle and the drum light remains on; can be restarted but stops again.
|
Overheating / Thermal Cut-Out Cycling | View Details |
| – |
Dryer takes too long to dry; cycles run much longer than usual and clothes are still damp.
|
Restricted Airflow / Reduced Heating Efficiency | View Details |
| – |
Dryer vibrates excessively and moves across the floor during operation.
|
Installation / Support Imbalance | View Details |
| – |
Dryer will not start at all; no lights or display when plugged in.
|
No Power / Main Supply Fault | View Details |
| – |
Water tank fills very quickly or overflows during a single cycle.
|
Condensation Inefficiency / Airflow Restriction | View Details |
No matching codes found