Condensation Inefficiency / Airflow Restriction
Water tank fills very quickly or overflows during a single cycle.
Advertisements
Possible Causes
Very dirty condenser, Blocked airflow through condenser housing, High ambient humidity and poor ventilation, Faulty condensate pump not evacuating water properly
How to Fix / Troubleshooting
Safety first: Unplug the dryer before cleaning internal components.
- Clean condenser thoroughly: Remove and rinse the condenser until water runs clear. Clean the housing and seals.
- Check filters: Clean all foam and mesh filters that protect the condenser.
- Improve room ventilation: Ensure the dryer is in a well-ventilated area and not in a confined, humid space.
- Inspect pump operation: If equipped with a pump to external drain, verify that water is being pumped out and that the hose is not kinked or blocked.