E19
Gram Time Calculation / Sensor Integration Fault

Dryer displays E19; may be associated with erratic time remaining display or sudden time jumps.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty moisture sensor input, Incorrect NTC readings, Main control PCB software error, Corrupted cycle parameters

How to Fix / Troubleshooting

Safety first: Unplug the dryer before testing sensors or accessing the control board.

  • Clean and check moisture sensor: Clean the sensor bars inside the drum with vinegar or mild detergent to remove residues. Ensure wiring to the sensor is intact.
  • Verify NTC sensors: Test the drum and exhaust NTC sensors for correct resistance at room temperature. Replace any sensor that is out of specification.
  • Power reset: Disconnect the dryer from mains for 10 minutes to reset the control. Reconnect and run a standard cotton cycle to see if E19 reappears.
  • Software/PCB issues: If sensors are good and cleaning does not help, the main control PCB may have a software or calculation fault. Replacement of the PCB or reprogramming by a service technician may be required.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements