E01
Dryer will not start; display shows E01 and a short beep when Start is pressed.
Door Interlock Circuit Fault
E02
Dryer stops shortly after start or will not start; E02 displayed, drum does not rotate.
Motor Start Failure / Motor Circuit Fault
E03
Dryer runs but does not heat; E03 appears after a few minutes of operation.
Heating Circuit Failure
E04
Dryer stops mid-cycle with E04; clothes remain damp and cycle time seems abnormal.
Moisture Sensor / Dryness Detection Fault
E05
Dryer stops and displays E05; may occur shortly after start, sometimes with no heat.
Exhaust / Airflow Restriction Fault
E06
Dryer displays E06 and stops; may be accompanied by unusual noises from the drum area.
Drum Rotation / Tacho Feedback Fault
E07
Dryer shows E07 and will not start; sometimes accompanied by a clicking sound from the control area.
Main Control PCB Communication / Internal Fault
E08
Dryer displays E08; cycle may stop early and drum may be hot to the touch.
Overheating / High Temperature Protection Fault
E09
Dryer shows E09 and stops; may occur on condenser or heat pump Gram dryers with water tank.
Condensate Pump / Water Level Fault
E10
Dryer will not start and displays E10; sometimes appears after a power surge or outage.
Power Supply / Voltage Detection Fault
E11
Dryer displays E11; buttons may not respond correctly or display may flicker.
User Interface / Control Panel Communication Fault
E12
Dryer shows E12; on heat pump models, drying performance is poor and cycle times are long.
Heat Pump System Fault (Heat Pump Models Only)
E13
Dryer displays E13; may be associated with sensor drying not working correctly.
NTC Temperature Sensor Fault (Drum / Exhaust)
E14
Dryer shows E14 and stops; may be accompanied by water under or inside the dryer on condenser/heat pump models.
Leakage / Overflow Protection Fault
E15
Dryer displays E15; drum light may work but cycle will not start.
Safety Thermostat / Thermal Fuse Open
E16
Dryer shows E16; may occur immediately after pressing Start, with a brief click from inside.
Door Lock Engagement Failure
E17
Dryer displays E17; on some models, the drum light flashes and the buzzer sounds repeatedly.
Drum Light / Auxiliary Power Circuit Fault
E18
Dryer shows E18; cycle may pause or stop unexpectedly, especially when changing programs.
Program Selector / Encoder Fault
E19
Dryer displays E19; may be associated with erratic time remaining display or sudden time jumps.
Time Calculation / Sensor Integration Fault
E20
Dryer shows E20; on some models, this appears when starting a cycle with a very small load.
Unbalanced Load / Motor Protection Fault
Symptom
Dryer display works but some buttons do not respond; no error code.
Faulty Keypad / Touch Control
Symptom
Dryer door is difficult to open after cycle or pops open during drying; no error code.
Door Latch / Hinge Misalignment
Symptom
Dryer drum does not turn, but the motor can be heard humming; no error code.
Broken or Slipped Drive Belt
Symptom
Dryer drum light stays on even when the door is closed and cycle is running; no error code.
Door Switch Stuck Open or Misadjusted
Symptom
Dryer emits a burning smell during operation; no error code.
Overheating or Foreign Object Contacting Heater
Symptom
Dryer leaks water onto the floor at the front or sides; no error code.
Condensate Drainage / Door Seal Leak
Symptom
Dryer makes loud rumbling or thumping noises during operation; no error code.
Worn Drum Support Rollers or Rear Drum Bearing
Symptom
Dryer powers on but will not start when Start/Pause is pressed; no error code.
Start Circuit / Door Interlock Not Confirmed
Symptom
Dryer produces a musty or moldy smell on clothes; no error code.
Bacterial Growth in Condenser or Lint Areas
Symptom
Dryer runs but clothes take much longer than usual to dry; no error code.
Restricted Airflow / Reduced Heating Efficiency
Symptom
Dryer runs but does not heat; no error code displayed, clothes remain cold and damp.
Open Heating Element or Thermal Cut-Out
Symptom
Dryer runs but timer does not count down; cycle seems to run indefinitely; no error code.
Auto-Dry Control / Moisture Sensing Failure
Symptom
Dryer squeals or squeaks continuously while running; no error code.
Idler Pulley or Drum Roller Lubrication Failure
Symptom
Dryer stops after a few minutes and clothes are still wet; no error code.
Overheat Trip Due to Blocked Airflow
Symptom
Dryer stops randomly and then restarts on its own; no error code.
Intermittent Power or Overheat Protection
Symptom
Dryer stops with clothes hot and very wrinkled; no error code.
Cool-Down Phase Not Operating
Symptom
Dryer vibrates excessively or moves across the floor during operation; no error code.
Cabinet Vibration / Drum Imbalance
Symptom
Dryer will not start at all; no lights or display.
No Power / Main Supply Failure
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E01 |
Dryer will not start; display shows E01 and a short beep when Start is pressed.
|
Door Interlock Circuit Fault | View Details |
| E02 |
Dryer stops shortly after start or will not start; E02 displayed, drum does not rotate.
|
Motor Start Failure / Motor Circuit Fault | View Details |
| E03 |
Dryer runs but does not heat; E03 appears after a few minutes of operation.
|
Heating Circuit Failure | View Details |
| E04 |
Dryer stops mid-cycle with E04; clothes remain damp and cycle time seems abnormal.
|
Moisture Sensor / Dryness Detection Fault | View Details |
| E05 |
Dryer stops and displays E05; may occur shortly after start, sometimes with no heat.
|
Exhaust / Airflow Restriction Fault | View Details |
| E06 |
Dryer displays E06 and stops; may be accompanied by unusual noises from the drum area.
|
Drum Rotation / Tacho Feedback Fault | View Details |
| E07 |
Dryer shows E07 and will not start; sometimes accompanied by a clicking sound from the control area.
|
Main Control PCB Communication / Internal Fault | View Details |
| E08 |
Dryer displays E08; cycle may stop early and drum may be hot to the touch.
|
Overheating / High Temperature Protection Fault | View Details |
| E09 |
Dryer shows E09 and stops; may occur on condenser or heat pump Gram dryers with water tank.
|
Condensate Pump / Water Level Fault | View Details |
| E10 |
Dryer will not start and displays E10; sometimes appears after a power surge or outage.
|
Power Supply / Voltage Detection Fault | View Details |
| E11 |
Dryer displays E11; buttons may not respond correctly or display may flicker.
|
User Interface / Control Panel Communication Fault | View Details |
| E12 |
Dryer shows E12; on heat pump models, drying performance is poor and cycle times are long.
|
Heat Pump System Fault (Heat Pump Models Only) | View Details |
| E13 |
Dryer displays E13; may be associated with sensor drying not working correctly.
|
NTC Temperature Sensor Fault (Drum / Exhaust) | View Details |
| E14 |
Dryer shows E14 and stops; may be accompanied by water under or inside the dryer on condenser/heat pump models.
|
Leakage / Overflow Protection Fault | View Details |
| E15 |
Dryer displays E15; drum light may work but cycle will not start.
|
Safety Thermostat / Thermal Fuse Open | View Details |
| E16 |
Dryer shows E16; may occur immediately after pressing Start, with a brief click from inside.
|
Door Lock Engagement Failure | View Details |
| E17 |
Dryer displays E17; on some models, the drum light flashes and the buzzer sounds repeatedly.
|
Drum Light / Auxiliary Power Circuit Fault | View Details |
| E18 |
Dryer shows E18; cycle may pause or stop unexpectedly, especially when changing programs.
|
Program Selector / Encoder Fault | View Details |
| E19 |
Dryer displays E19; may be associated with erratic time remaining display or sudden time jumps.
|
Time Calculation / Sensor Integration Fault | View Details |
| E20 |
Dryer shows E20; on some models, this appears when starting a cycle with a very small load.
|
Unbalanced Load / Motor Protection Fault | View Details |
| – |
Dryer display works but some buttons do not respond; no error code.
|
Faulty Keypad / Touch Control | View Details |
| – |
Dryer door is difficult to open after cycle or pops open during drying; no error code.
|
Door Latch / Hinge Misalignment | View Details |
| – |
Dryer drum does not turn, but the motor can be heard humming; no error code.
|
Broken or Slipped Drive Belt | View Details |
| – |
Dryer drum light stays on even when the door is closed and cycle is running; no error code.
|
Door Switch Stuck Open or Misadjusted | View Details |
| – |
Dryer emits a burning smell during operation; no error code.
|
Overheating or Foreign Object Contacting Heater | View Details |
| – |
Dryer leaks water onto the floor at the front or sides; no error code.
|
Condensate Drainage / Door Seal Leak | View Details |
| – |
Dryer makes loud rumbling or thumping noises during operation; no error code.
|
Worn Drum Support Rollers or Rear Drum Bearing | View Details |
| – |
Dryer powers on but will not start when Start/Pause is pressed; no error code.
|
Start Circuit / Door Interlock Not Confirmed | View Details |
| – |
Dryer produces a musty or moldy smell on clothes; no error code.
|
Bacterial Growth in Condenser or Lint Areas | View Details |
| – |
Dryer runs but clothes take much longer than usual to dry; no error code.
|
Restricted Airflow / Reduced Heating Efficiency | View Details |
| – |
Dryer runs but does not heat; no error code displayed, clothes remain cold and damp.
|
Open Heating Element or Thermal Cut-Out | View Details |
| – |
Dryer runs but timer does not count down; cycle seems to run indefinitely; no error code.
|
Auto-Dry Control / Moisture Sensing Failure | View Details |
| – |
Dryer squeals or squeaks continuously while running; no error code.
|
Idler Pulley or Drum Roller Lubrication Failure | View Details |
| – |
Dryer stops after a few minutes and clothes are still wet; no error code.
|
Overheat Trip Due to Blocked Airflow | View Details |
| – |
Dryer stops randomly and then restarts on its own; no error code.
|
Intermittent Power or Overheat Protection | View Details |
| – |
Dryer stops with clothes hot and very wrinkled; no error code.
|
Cool-Down Phase Not Operating | View Details |
| – |
Dryer vibrates excessively or moves across the floor during operation; no error code.
|
Cabinet Vibration / Drum Imbalance | View Details |
| – |
Dryer will not start at all; no lights or display.
|
No Power / Main Supply Failure | View Details |
No matching codes found