New World
Sensor-Controlled Drying Calibration / Moisture Sensing Issue
Dryer display shows incorrect remaining time or jumps suddenly during the cycle.
Advertisements
Possible Causes
Dirty moisture sensor bars, Poor contact on sensor wiring, Software estimation based on load size, Faulty NTC sensor affecting timing
How to Fix / Troubleshooting
Safety first: Unplug the dryer before cleaning internal sensors.
- Clean moisture sensors: Wipe the metal sensor bars inside the drum with a cloth and mild cleaner to remove residue.
- Check wiring: Inspect the moisture sensor wiring harness and connectors for secure fit.
- NTC sensor check: If drying performance is also affected, test the NTC temperature sensor and replace if out of specification.
- Load size: Be aware that sensor dryers adjust time based on load moisture; small loads may cause time jumps and are normal behavior.