Vedette Condensate Drainage / Tank Overflow

Dryer leaks water onto the floor during or after a cycle

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condensate drain channel, Full or mis-seated water tank, Cracked condensate hose, Leaking pump housing

How to Fix / Troubleshooting

Safety first: Unplug the dryer and mop up any standing water to prevent slipping.

Step-by-step checks:

  • Check water tank: Remove, empty, and clean the water tank. Ensure it is reinserted fully until it clicks.
  • Inspect drain channel: Access the area under the condenser and clean any lint or sludge from the drain channel leading to the pump or tank.
  • Examine hoses: Remove the lower front or rear panel and inspect condensate hoses for cracks or loose connections. Replace or secure as needed.
  • Pump housing: Check the pump body for leaks while running a short cycle. Replace the pump if it leaks.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condensate Hoses / Water Tank