Possible Causes
Blocked condensate drain channel, Full or mis-seated water tank, Cracked condensate hose, Leaking pump housing
How to Fix / Troubleshooting
Safety first: Unplug the dryer and mop up any standing water to prevent slipping.
Step-by-step checks:
- Check water tank: Remove, empty, and clean the water tank. Ensure it is reinserted fully until it clicks.
- Inspect drain channel: Access the area under the condenser and clean any lint or sludge from the drain channel leading to the pump or tank.
- Examine hoses: Remove the lower front or rear panel and inspect condensate hoses for cracks or loose connections. Replace or secure as needed.
- Pump housing: Check the pump body for leaks while running a short cycle. Replace the pump if it leaks.