E07
BougeRV Protective Earth / Grounding Fault

Charger displays E07 and refuses to start; often associated with reversed line/neutral or missing ground.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open ground in supply circuit, High resistance ground connection at input terminal, Corroded ground pin on plug-in model, Faulty ground monitoring circuit on main control board

How to Fix / Troubleshooting

Shock hazard: Do not use the charger if a ground fault is indicated. A missing or poor ground can be life-threatening.

  • Step 1 – Test outlet ground: For plug-in BougeRV chargers, use a receptacle tester to verify correct wiring and presence of ground. For hardwired units, have an electrician test the ground impedance.
  • Step 2 – Inspect ground conductor: With power off, open the input wiring compartment and confirm the ground wire is securely attached to the ground terminal and that the terminal is tight to the chassis.
  • Step 3 – Clean contacts: On plug-in models, clean the ground pin with electrical contact cleaner if corrosion is present. Replace the plug if the pin is badly pitted.
  • Step 4 – Internal ground strap: Verify that any internal ground straps between the BougeRV metal chassis and PCB ground points are intact and securely fastened.
  • Step 5 – Board-level fault: If the supply ground is verified good and connections are tight but E07 persists, the ground monitoring circuit on the BougeRV main control board may be defective and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

BougeRV Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements