E16
BougeRV
Current Sensor Calibration Fault
Charger shows E16 and will not start; may be labeled as "calibration error".
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Drifted or failed Hall-effect current sensor, Corrupted calibration data in EEPROM, Loose sensor connector, Main board analog front-end failure
How to Fix / Troubleshooting
Safety: Current measurement is critical for safe operation. Do not bypass or defeat current sensors.
- Step 1 – Power reset: Turn off power for several minutes and restore to clear transient errors.
- Step 2 – Check sensor connections: With power off, open the charger and locate the current sensor (often a ring or block around the output conductors). Ensure its connector is fully seated on the main board.
- Step 3 – Inspect for damage: Look for cracks in the sensor housing or signs of overheating on the conductors passing through it.
- Step 4 – Factory reset / recalibration: If BougeRV provides a service menu or app function for sensor calibration, follow their procedure exactly.
- Step 5 – Replace sensor or board: If recalibration fails or is unavailable, replace the BougeRV output current sensor. If E16 persists, the main control board's measurement circuitry may need replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
BougeRV Output Current Sensor
Check Price on Amazon