Easee
Intermittent Charging / Nuisance Trips
Charger intermittently stops charging before battery is full, then resumes later
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Marginal earth leakage near RCD threshold, Fluctuating supply voltage, Thermal derating due to heat, Load balancing temporarily reducing current to zero
How to Fix / Troubleshooting
Note: Intermittent stops are often protective responses rather than outright failures.
- 1. Check app logs: Review the Easee app or portal for event logs indicating the reason for each stop (e.g. temperature, RCD, load balancing).
- 2. Monitor temperature and environment: Ensure the charger is not overheating or exposed to direct sun during long sessions.
- 3. Inspect for moisture: Look for signs of condensation or water ingress that could cause transient leakage currents.
- 4. Simplify load management: Temporarily disable or relax load balancing settings to see if stability improves.
- 5. Electrical tests (qualified only): Have an electrician test earth leakage, insulation resistance, and supply stability.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Easee RCD/RCM module
Check Price on Amazon
We may earn a commission from links on this page.