Easee Moisture Ingress / IP Seal Failure

Water or condensation visible inside the charger enclosure or behind the front cover

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Improperly tightened cable gland, Damaged enclosure gasket, Incorrect mounting orientation, Cracked housing

How to Fix / Troubleshooting

Warning: Moisture inside an energized charger is hazardous. Isolate power before opening.

  • 1. Turn off power: Switch off the upstream breaker and verify the charger is de-energized.
  • 2. Open enclosure: Remove the front module and gently dry any visible moisture with a lint-free cloth. Allow the unit to air dry completely.
  • 3. Inspect seals: Check the perimeter gasket, cable gland, and any knockouts for damage or improper installation.
  • 4. Reseat or replace gland: Tighten the cable gland to compress the seal around the cable. Replace if cracked or deformed.
  • 5. Improve mounting: Ensure the charger is mounted vertically as specified and that water cannot run down the cable into the gland.
  • 6. Replace damaged housing: If the enclosure is cracked or warped, replace the housing or complete backplate.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Easee enclosure gasket
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements