Heidelberg
Display Backlight / LCD Failure
Charger’s integrated display is very dim or unreadable, while LEDs and charging function normally.
Advertisements
Possible Causes
Aged or failed backlight LEDs, Loose display connector, Damaged LCD from impact, Low contrast setting in configuration
How to Fix / Troubleshooting
Safety first: Isolate mains before accessing the display module.
- 1. Check settings:
- If accessible, adjust display brightness/contrast in the charger menu.
- 2. Inspect display module:
- Open the housing and locate the display board.
- Ensure its connector to the main board is firmly seated.
- 3. Look for damage:
- Check for cracks in the LCD or signs of moisture.
- 4. Replace display:
- If the backlight remains dim or off, replace the display module with a Heidelberg‑approved spare.
Advertisements