E15
Heidelberg Internal Energy Meter Communication Error

Charger displays E15, integrated energy meter readings are unavailable or show dashes, billing or logging fails.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty internal MID energy meter, Broken communication link between meter and main board (e.g., RS‑485 or SPI), Loose meter connector, Firmware mismatch between meter and controller

How to Fix / Troubleshooting

Safety first: Isolate mains before accessing the internal meter.

  • 1. Check display/app:
    • Verify if any energy values are shown in the charger UI or app.
    • If all values are missing or zero, suspect meter communication.
  • 2. Inspect internal meter:
    • Open the housing and locate the internal energy meter module (often a DIN‑style or PCB‑mounted meter).
    • Check that its connectors are firmly seated.
  • 3. Communication wiring:
    • Trace the communication wires (RS‑485 or similar) between the meter and main board.
    • Look for damage or loose terminals.
  • 4. Power cycle:
    • After reseating connectors, power cycle the charger and check if readings return.
  • 5. Replace meter if necessary:
    • If E15 persists and wiring is intact, replace the internal energy meter module with the Heidelberg‑approved part.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Internal Energy Meter Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements