E19
Heidelberg Enclosure Tamper / Cover Interlock Fault

Charger displays E19, integrated door or cover switch error, unit refuses to charge with cover closed.

Advertisements

Possible Causes

Faulty cover microswitch, Misaligned cover not actuating switch, Broken switch wiring, Bypassed or tampered interlock circuit

How to Fix / Troubleshooting

Safety first: The cover interlock prevents access to live parts. Never bypass it permanently. Isolate mains before adjusting.

  • 1. Check cover alignment:
    • Ensure the front cover is properly seated and all screws are tightened.
    • Look for warped plastic or obstructions preventing full closure.
  • 2. Inspect interlock switch:
    • Open the housing (with power off) and locate the cover microswitch or reed switch.
    • Verify that the actuator or magnet aligns correctly when the cover is closed.
  • 3. Test switch continuity:
    • With a multimeter, check the switch contacts while manually actuating it.
    • If no change in continuity, replace the switch.
  • 4. Check wiring:
    • Inspect the cable from the switch to the main board for breaks or loose connectors.
  • 5. Replace faulty parts:
    • Install a new cover interlock switch if defective.
    • Never short the interlock terminals as a permanent fix.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Cover Interlock Microswitch