E006
NewMotion Internal Overtemperature Shutdown

Charger displays E006; LED ring flashes red rapidly; unit reports overtemperature and stops charging.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked ventilation around charger housing, High ambient temperature exceeding spec, Failing internal temperature sensor on main PCB, Overheating power module or contactor due to loose connections

How to Fix / Troubleshooting

Safety first: Components may be hot. Allow the unit to cool before opening.

  • Check installation location: Ensure the NewMotion charger is not installed in direct sunlight or near heat sources. Maintain the manufacturer’s recommended clearance around the unit for airflow.
  • Inspect vents: Clean any dust, cobwebs, or debris from ventilation slots on the housing. Do not block vents with covers or insulation.
  • Check cable glands: Verify that cable glands are tight but not over-tightened to the point of deforming the enclosure and restricting airflow.
  • Internal inspection: After isolating power, open the unit and inspect the power module, contactor, and terminal block for signs of overheating (discoloration, melted insulation).
  • Tighten power connections: Loose terminals can cause localized heating. Retorque all high-current connections to the manufacturer’s specified torque.
  • Sensor verification: Locate the internal NTC temperature sensor on the main PCB or heat sink. If it is detached or damaged, reattach or replace the PCB/module.
  • Test after cooldown: Once cooled and reassembled, restore power and monitor temperature readings via the NewMotion app if available. If E006 recurs quickly, a failing sensor or module is likely.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Power Module / Main Control PCB Temperature Sensor