E007
NewMotion Control Pilot (CP) Signal Failure

Charger shows E007; LED ring alternates red and green; charging is disabled due to pilot signal fault.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Broken CP conductor in tethered cable, Corroded CP pin in Type 2 socket, Faulty CP driver circuit on main PCB, Incorrect wiring of CP to socket terminals

How to Fix / Troubleshooting

Safety first: Isolate power before accessing internal wiring or socket terminals.

  • Visual check of connector: Inspect the Type 2 socket or tethered plug for damage to the small CP pin. Clean light corrosion with contact cleaner and a non-metallic brush.
  • Check cable strain relief: Ensure the tethered cable is properly clamped and not pulling on internal CP wiring.
  • Continuity test: With power off, use a multimeter to check continuity of the CP wire from the main PCB CP terminal to the socket/plug CP pin. Repair or replace the cable if open.
  • Inspect PCB connector: Verify the CP wire is firmly seated in the control board terminal block or plug-in connector.
  • Test with another cable: For socketed units, try a different Type 2 cable to rule out a cable-side CP fault.
  • PCB replacement: If wiring and connector are good but E007 persists, the CP driver circuit on the main control PCB may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control Pilot Circuit / Type 2 Socket or Tethered Cable