E008
NewMotion Proximity Pilot (PP) Detection Error

Charger reports E008; LED ring shows red with brief blue flashes; unit indicates proximity (PP) fault and will not lock or start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect PP resistor in cable, Damaged PP contact in socket, Broken PP wire in tethered cable, Faulty PP sensing circuit on main PCB

How to Fix / Troubleshooting

Safety first: Disconnect power before testing PP wiring.

  • Test with another cable: For socketed NewMotion chargers, plug in a known-good Type 2 cable. If E008 disappears, the original cable’s PP resistor or wiring is faulty.
  • Inspect PP pin: Examine the PP pin in the socket/plug for deformation or contamination. Clean gently if needed.
  • Measure PP resistance: With the cable disconnected from the charger, measure resistance between PP and PE (earth) on the cable plug. Compare to standard values (e.g., ~220 Ω for 32 A). Replace the cable if out of spec.
  • Check internal PP wiring: For tethered units, verify continuity of the PP conductor from the main PCB to the plug. Repair or replace the tethered cable if open or shorted.
  • PCB diagnosis: If PP wiring and cable are correct, the PP sensing input on the main PCB may be faulty and require board replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Proximity Pilot Circuit / Type 2 Cable
Check Price on Amazon