E024
NewMotion Emergency Stop / External Interlock Activated

Charger reports E024; LED ring flashes red; app indicates emergency stop input active.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

External E-stop button engaged, Open circuit on interlock terminals, Miswired external control input, Faulty digital input on PCB

How to Fix / Troubleshooting

Safety first: Identify why the emergency stop was triggered before resetting.

  • Locate E-stop: Find any external emergency stop button or interlock wired to the charger. Ensure it has not been pressed or latched.
  • Reset E-stop: Twist or pull to reset the button according to its design. Confirm the contacts close properly.
  • Check wiring: With power off, inspect the wiring from the E-stop to the charger’s interlock terminals. Tighten loose screws and repair any breaks.
  • Bypass test (qualified only): Temporarily bridge the interlock terminals at the charger to confirm whether the input circuit is working. If E024 clears, the issue is in the external wiring or device.
  • PCB input fault: If E024 remains even with a proper bridge, the digital input channel on the main PCB may be faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

External E-stop Circuit / Main Control PCB Input