CT ERROR
OpenEVSE
Current Transformer Signal Fault
Display shows 'CT ERROR' or current readings are zero or nonsensical while charging.
Advertisements
Possible Causes
CT sensor not clamped around conductor, CT installed backwards or on wrong wire, Broken CT lead or connector, Failed CT sensor or CT board
How to Fix / Troubleshooting
Safety first: Turn off power before moving the CT or opening the enclosure.
- Step 1 – Verify CT placement: Ensure the CT is clamped fully around the correct line conductor (usually L1) and that the jaws are fully closed.
- Step 2 – Orientation: Some CTs are directional. Check for an arrow or marking indicating current flow direction and orient accordingly.
- Step 3 – Inspect wiring: Follow the CT leads to the CT board or main board. Ensure the connector is fully seated and wires are not pinched or broken.
- Step 4 – Compare with clamp meter: If possible, measure current with an external clamp meter and compare to EVSE readings. If the CT reads zero or wildly off, replace the CT sensor or CT board.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Current Transformer (CT) Sensor
Check Price on Amazon