CT ERROR
OpenEVSE Current Transformer Signal Fault

Display shows 'CT ERROR' or current readings are zero or nonsensical while charging.

Advertisements

Possible Causes

CT sensor not clamped around conductor, CT installed backwards or on wrong wire, Broken CT lead or connector, Failed CT sensor or CT board

How to Fix / Troubleshooting

Safety first: Turn off power before moving the CT or opening the enclosure.

  • Step 1 – Verify CT placement: Ensure the CT is clamped fully around the correct line conductor (usually L1) and that the jaws are fully closed.
  • Step 2 – Orientation: Some CTs are directional. Check for an arrow or marking indicating current flow direction and orient accordingly.
  • Step 3 – Inspect wiring: Follow the CT leads to the CT board or main board. Ensure the connector is fully seated and wires are not pinched or broken.
  • Step 4 – Compare with clamp meter: If possible, measure current with an external clamp meter and compare to EVSE readings. If the CT reads zero or wildly off, replace the CT sensor or CT board.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Current Transformer (CT) Sensor
Check Price on Amazon