OpenEVSE Energy Measurement Calibration Error

OpenEVSE reports wildly inaccurate energy or kWh usage compared to utility meter or vehicle logs.

Advertisements

Possible Causes

Incorrect CT calibration constants in firmware, Wrong CT type installed, CT not fully closed or on wrong conductor, Faulty CT sensor

How to Fix / Troubleshooting

Safety first: Turn off power before moving the CT.

  • Step 1 – Verify CT installation: Ensure the CT is fully closed around the correct line conductor and not around both line and neutral.
  • Step 2 – Check firmware settings: Confirm that the CT type and calibration values in the firmware match the installed CT.
  • Step 3 – Compare with clamp meter: Measure current with an external clamp meter and adjust calibration if your firmware allows.
  • Step 4 – Replace CT: If readings remain inconsistent, replace the CT sensor or CT board.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Current Transformer (CT) Sensor