E018
Rivian Internal Energy Meter / Measurement Fault

Rivian charger shows E018; app indicates ‘Metering error’ and energy reporting is disabled or inaccurate

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed metering IC on control board, Loose CT or voltage sense wiring, Corrupted calibration data, Electrical noise on measurement lines

How to Fix / Troubleshooting

Safety first: Metering faults do not usually affect basic safety, but may impact billing or reporting.

  • Step 1 – Power cycle: Turn breaker OFF for 1 minute, then ON.
  • Step 2 – Check wiring to CTs: With power OFF and cover removed, ensure current transformers and voltage sense leads are firmly connected to the metering section of the control board.
  • Step 3 – Compare readings: During a charge, compare the charger’s reported current/energy with an external clamp meter (by a qualified person). Large discrepancies confirm a metering issue.

If E018 persists, the metering circuitry on the control board is likely defective and the board should be replaced.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Rivian Wall Charger Metering Circuit
Check Price on Amazon

We may earn a commission from links on this page.