Zencar Metering Inaccuracy

Charger shows significantly inaccurate kWh or current readings compared to other meters.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Drifted calibration of internal meter, Loose CT connections, Incorrect CT orientation, Firmware bug in measurement algorithm

How to Fix / Troubleshooting

Safety first: Turn off power before touching CTs or meter wiring.

  • Compare readings: Use a known-accurate meter or utility meter to compare consumption over a full charge session.
  • Inspect CTs: For models with internal or external CTs, ensure they are clamped fully around the correct conductors and oriented as per arrows.
  • Check connections: Verify CT leads are firmly connected to the internal kWh meter module or main board.
  • Calibration/reset: If Zencar provides a calibration or reset function, follow the documented procedure.
  • Persistent large errors: Replace the internal kWh meter module or main control PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Internal kWh Meter Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements