E08
Zencar Line Wiring / Phase Detection Error

Display shows E08 and charging does not start; often occurs when using adapters or extension cords.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect phase configuration, Use of non-approved adapters, Reversed line and neutral, Shared neutral on multi-wire branch circuit, Faulty line sensing circuit

How to Fix / Troubleshooting

Safety first: Incorrect wiring can create shock and fire hazards. Only qualified persons should modify wiring.

  • Remove adapters: Disconnect any third-party adapters or extension cords. Plug the Zencar charger directly into a properly wired receptacle or hardwired circuit.
  • Verify wiring configuration: For single-phase models, confirm correct line/neutral/ground connections. For split-phase or three-phase capable units, ensure phases are connected as per Zencar wiring diagram.
  • Check for shared neutrals: Ensure the charger is on a dedicated circuit without shared neutrals that can confuse phase detection.
  • Inspect internal terminals: With power OFF, verify that L1, L2 (if used), N, and PE are correctly landed and labeled inside the charger.
  • If wiring is correct and E08 remains: The line sensing circuit on the main control PCB may be defective and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon