E09
Zencar Proximity / Lock Switch Fault (Connector Proximity Pilot)

Charger shows E09; vehicle may not recognize the charger or shows 'charging station error'.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged proximity switch in handle, Broken proximity wire in cable, Stuck mechanical button on J1772/Type 2 connector, Faulty proximity input on control board

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker before inspecting the connector wiring.

  • Check connector button: On J1772 handles, press and release the latch button several times to ensure it moves freely and is not stuck partially depressed.
  • Inspect connector head: Look for cracks or impact damage around the latch area that could affect the internal proximity switch.
  • Flex test the cable: With power OFF, gently flex the cable near the handle while monitoring continuity (if equipped) or observing if the error appears/disappears. Intermittent behavior suggests a broken proximity conductor; replace the output charging cable assembly.
  • Check board connection: Verify the proximity wire connector is firmly seated on the main control PCB and not corroded.
  • If all wiring is intact: The proximity input circuit on the main control PCB may be faulty and require board replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Output Charging Cable Assembly
Check Price on Amazon