F1
Balay General Temperature Sensor Error

Freezer displays F1 and may not maintain correct temperature; sometimes accompanied by beeping.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Any of the NTC sensors (cabinet, evaporator, ambient) out of range, Sensor wiring harness damage, Connector oxidation on PCB, Short between sensor leads

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing sensors or the control board.

  • Power reset: Disconnect power for 10 minutes. If F1 returns, proceed.
  • Check visible sensors: Inspect cabinet and evaporator sensors for damage or dislodging (see E1 and E2 procedures).
  • Inspect wiring harness: Follow the sensor cables as far as accessible, looking for pinched or cut sections.
  • Reseat PCB connectors: Access the main control board and reseat all sensor connectors.
  • Test sensors: If you have a multimeter, measure resistance of each sensor and compare to Balay specifications. Replace any sensor that is open, shorted, or far out of expected range.

If all sensors test correctly, the main control board may be misreading them and likely needs replacement by a technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Temperature Sensor Set (Cabinet / Evaporator / Ambient)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements