Balay Temperature Regulation / Thermostat Control Problem

Freezer temperature fluctuates widely; sometimes too warm, sometimes too cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty cabinet temperature sensor, Sticking mechanical thermostat (on older models), Loose sensor probe, Main control board logic issues

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing sensors or thermostat controls.

  • Check settings: Ensure the temperature is set correctly and that SuperFreeze is not left on permanently.
  • Inspect sensor location: Make sure the cabinet sensor is not touching the evaporator or covered by food packaging, which can cause false readings.
  • Test sensor or thermostat: For electronic models, follow the NTC sensor tests (see E2). For mechanical thermostats, listen for a click when turning the dial from warm to cold; no click may indicate failure.
  • Replace faulty part: Install a new Balay cabinet NTC sensor or Balay mechanical thermostat as appropriate for your model.

If fluctuations persist after replacing the sensor/thermostat, the main control board may be defective and should be evaluated by a technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet Temperature Sensor or Thermostat
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements