Possible Causes

Failed LED light module, Faulty door switch, Loose light connector, Open circuit in light wiring

How to Fix / Troubleshooting

Safety first: Unplug the freezer before removing light covers or accessing wiring.

Check door switch:

  • Press the door switch manually (if visible) and see if the light flickers or comes on.
  • If the switch feels loose or sticky, it may be faulty.

Inspect light module:

  • Remove the light lens and check the LED module and connector.
  • Ensure the connector is fully seated.

Corrective actions:

  • Replace door switch: If the switch does not change state electrically, replace it with a Blomberg-compatible part.
  • Replace LED module: If the module is non-functional, install a new LED light assembly.

Test: Restore power and open the door to confirm proper light operation.