F8
Fisher & Paykel Defrost Sensor Range / Calibration Error

Freezer displays F8, ice buildup may be present, or unit may not enter defrost correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect defrost sensor value (out of calibration), wrong replacement thermistor installed, sensor not properly attached to evaporator, main control board firmware issue

How to Fix / Troubleshooting

Safety: Disconnect power before working near the evaporator or wiring.

Steps:

  • Verify recent repairs: If a thermistor was recently replaced, confirm that a genuine Fisher & Paykel part with the correct rating was installed.
  • Check sensor mounting: Ensure the defrost/evaporator thermistor is firmly clipped to the evaporator tubing in the correct location, not hanging loose in the air.
  • Inspect wiring: Look for spliced wires or non-standard connectors that may add resistance and affect readings. Restore proper connections where possible.
  • Reset control: After correcting any issues, unplug the freezer for 10 minutes to reset the control. If F8 returns, the main control board may be misreading the sensor and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator / Defrost Thermistor
Check Price on Amazon

We may earn a commission from links on this page.