Fisher & Paykel No Cooling – Compressor Not Running

Freezer not cooling at all, interior at room temperature, lights may work but no cold air.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay/overload, defective main control board, open compressor winding, failed inverter module (on inverter models)

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing the compressor or control board. Do not attempt to open the sealed system.

Steps:

  • Listen for compressor: After plugging in briefly, listen at the back. If you hear only a click or nothing at all, unplug and continue.
  • Check control settings: Ensure the freezer is switched on at the control panel and not in demo mode (if applicable).
  • Access compressor compartment: Remove the rear lower panel to expose the compressor and start device.
  • Inspect start device: Remove the start relay/overload from the compressor. If it rattles when shaken or shows burn marks, replace the compressor start relay/overload.
  • Control board: If the start device is good and the compressor still does not receive power, the main control board may be faulty and should be replaced.
  • Compressor failure: If a technician confirms open or shorted windings, the compressor must be replaced by a licensed refrigeration technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay / Overload
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements