Galanz Door Switch Stuck Open / Light Stays On

Freezer interior light stays on even when the door is closed, causing warming and condensation near the light.

Advertisements

Possible Causes

Stuck or broken door switch, Misaligned door not pressing switch fully, Shorted light control on main board

How to Fix / Troubleshooting

Safety: Unplug the freezer before working on the door switch or light circuit.

  • Check door alignment: Ensure the door closes squarely and fully. Adjust leveling feet so the cabinet is not twisted, which can prevent the door from contacting the switch.
  • Test the switch: Press and release the door switch by hand. The light should turn off when pressed. If it does not, the switch may be faulty.
  • Replace the switch: Remove the switch from the frame (usually pried out gently or held by a screw) and install a new Galanz door switch. Transfer wires one at a time.
  • Control board issue: If the light remains on even with the switch disconnected, the main control board may be shorted and require replacement.
  • Prevent heat damage: Until repaired, you can temporarily remove the bulb or disconnect the light module to prevent warming the freezer interior.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.