door
GE Door Ajar Alarm / Door Switch Fault

GE freezer display shows DOOR or a door icon and alarm sounds frequently

Advertisements

Possible Causes

Door not fully closing, Warped or damaged door gasket, Failed door switch, Misaligned door or hinges

How to Fix / Troubleshooting

Safety: Most checks can be done with power on, but unplug the freezer before removing the door switch or working with wiring.

Steps to address DOOR alarm:

  • Check for obstructions: Inspect shelves and baskets to ensure no items are preventing the door from closing fully. Rearrange contents as needed.
  • Inspect gasket: Look for tears, gaps, or hardened sections of the GE freezer door gasket. Close the door on a sheet of paper at several points; if the paper pulls out easily, the seal is weak.
  • Adjust leveling: Use a level to ensure the freezer is slightly tilted back so the door closes by itself. Adjust front leveling legs as needed.
  • Test door switch: Locate the door switch (usually in the front frame area). With the door open, press the switch plunger; the interior light should turn off and the alarm should stop after a short delay. If nothing changes, the switch may be faulty.
  • Replace door switch: Unplug the freezer, pry the switch out gently, disconnect the wires, and install a new GE door switch. Reconnect wires and snap the switch back into place.
  • Re-test: Close the door and confirm that the DOOR alarm no longer triggers when the door is properly shut.

Note: If the alarm persists despite a good switch and gasket, the main control board input circuit may be defective and require professional service.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.