Gorenje
Erratic Temperature Sensing
Temperature display fluctuates rapidly or shows unrealistic values (e.g., +20°C to -30°C within minutes).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose or intermittent NTC sensor connection, Damaged sensor cable, Electrical noise or interference on sensor lines, Faulty ADC on main PCB
How to Fix / Troubleshooting
Safety: Disconnect power before handling sensors or PCB connectors.
- Inspect sensor wiring: Locate the compartment and evaporator sensors and follow their cables to the PCB. Look for damage or pinched sections.
- Reseat connectors: Unplug and reconnect sensor plugs at both ends to ensure good contact.
- Test sensors: Measure resistance at stable temperatures and check for stable readings. Replace any sensor with fluctuating or intermittent resistance.
- PCB issue: If sensors and wiring are good but readings remain erratic, the main PCB’s analog input may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Freezer Temperature Sensor (NTC)
Check Price on Amazon