Gram Display PCB or Power Supply Fault

Freezer display is blank or flickering, but the compressor may still run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed display PCB, Loose display connector, Weak low-voltage power supply on main PCB, Moisture ingress into control panel

How to Fix / Troubleshooting

Safety first: Unplug the freezer before opening the control panel.

Step-by-step checks:

  • 1. Power reset: Unplug for 5 minutes, then reconnect. Observe if the display returns to normal.
  • 2. Access display panel: Remove screws securing the front/top control panel and gently pull it forward.
  • 3. Check connectors: Ensure the ribbon cable or wiring harness between the display and main PCB is firmly seated.
  • 4. Inspect for moisture: Look for condensation or water marks. Allow the panel to dry completely if wet.
  • 5. Replace display PCB: If the display remains blank or flickers despite good connections, replace the display PCB with a Gram-compatible part.

When to call a technician: If you are not comfortable handling electronic boards or if the main PCB power supply is suspected, contact a technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Display PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements