Hotpoint-Ariston
Door Switch Stuck Open / Misalignment
Freezer interior light stays on even when the door is closed, causing warming and condensation.
Advertisements
Possible Causes
Broken or jammed door switch, Misaligned door not pressing switch, Faulty reed sensor not detecting magnet
How to Fix / Troubleshooting
Safety first: Unplug the freezer before adjusting or replacing the switch.
- Check light through door gap: In a dark room, close the door and look for light leakage around the gasket.
- Inspect switch: Locate the door switch and ensure it moves freely. Clean any debris around it.
- Adjust door alignment: Level the unit and adjust hinges so the door fully depresses the switch.
- Replace faulty switch/sensor: If the light remains on, replace the door switch or reed sensor with the correct Hotpoint-Ariston part.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Switch / Reed Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements