Hotpoint-Ariston
Hotpoint-Ariston Freezers Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
A1
Freezer display shows error A1 and the temperature is too high; food feels soft or partially thawed.
High Temperature Alarm / Prolonged Door Open Detection
A2
Freezer shows error A2 and the temperature is too low or fluctuating; some items may be over-frozen or frost-covered.
Temperature Sensor / Thermistor Fault
A3
Error A3 on display; freezer struggles to maintain temperature and may run continuously.
Evaporator Defrost Sensor / Evaporator NTC Fault
A4
Freezer shows error A4; unit may not defrost properly and frost builds up on the back wall.
Defrost Heater Circuit Fault
A5
Error A5 displayed; freezer may not cool correctly or may cycle erratically.
Ambient Temperature Sensor Fault
A6
Freezer shows error A6; compressor may not start or may shut down quickly.
Compressor Start / Inverter Communication Fault
AL01
Alarm code AL01; continuous beeping and high temperature warning.
High Temperature Alarm (Prolonged)
AL02
Alarm code AL02; low temperature alarm, freezer may be much colder than setpoint.
Overcooling Due to Sensor or Control Fault
AL03
Alarm code AL03; door alarm sounds even when the door appears closed.
Door Open Detection Fault
F01
Error F01 on display; freezer is not cooling or behaves unpredictably.
Main Control Board Failure
F02
Error F02; interior fan may not run and cooling is poor or uneven.
Evaporator Fan Motor Fault
F03
Error F03; freezer temperature reading is clearly wrong (e.g., shows -18°C but food is soft).
Freezer Compartment Temperature Sensor Error
F04
Error F04; freezer may not defrost and frost accumulates on the evaporator cover.
Defrost Sensor / Thermostat Error
F05
Error F05; freezer may not cool and compressor may not run.
Compressor Relay / Overload Fault
F06
Error F06; display or control panel may be unresponsive or show erratic behavior.
User Interface / Display Board Communication Fault
F07
Error F07; freezer may not maintain set temperature and may run continuously.
Heater or Relay Stuck On / Off (Control Board Logic Fault)
F08
Error F08; interior light or fan may not operate correctly when door is opened or closed.
Door Switch / Reed Sensor Fault
F09
Error F09; freezer may not respond to temperature changes or may reset unexpectedly.
EEPROM / Configuration Memory Error
F10
Error F10; freezer may not cool and compressor may not be commanded on.
Compressor Control Circuit Error
F11
Error F11; alarm beeps and display may flash, but cooling may appear normal initially.
Communication Error Between Display and Main Board
F12
Error F12; freezer may not accept user inputs and may be stuck in one mode.
User Interface Keypad Fault
Symptom
Bad smell or foul odor coming from inside the freezer, even after removing spoiled food.
Persistent Odor Contamination
Symptom
Burning smell or electrical odor coming from the freezer.
Overheating Electrical Component
Symptom
Excessive frost or ice buildup on the back wall or around drawers in a No Frost Hotpoint-Ariston freezer.
Defrost System Failure / Air Leak
Symptom
Freezer displays temperature but does not respond to button presses or touch controls.
Control Panel Unresponsive
Symptom
Freezer door will not close properly or pops open after being shut.
Door Alignment / Seal Failure
Symptom
Freezer interior light stays on even when the door is closed, causing warming and condensation.
Door Switch Stuck Open / Misalignment
Symptom
Freezer interior light works but compressor and fan do not start; no humming or clicking sounds.
No Start Condition (Control or Power Circuit)
Symptom
Freezer is too cold; ice cream is rock hard and items show freezer burn even at moderate settings.
Overcooling / Thermostat or Sensor Misregulation
Symptom
Freezer makes loud humming, buzzing, or clicking noises from the back.
Compressor or Condenser Fan Noise
Symptom
Freezer makes loud knocking or banging noises, especially when the compressor starts or stops.
Refrigerant Line or Compressor Mount Vibration
Symptom
Freezer not cooling at all; interior is at room temperature, light may work but there is no cold air.
Complete Loss of Cooling
Symptom
Freezer produces a high-pitched whine or squeal from inside the cabinet.
Evaporator Fan Motor Noise
Symptom
Freezer runs but does not get cold enough; temperature stays above -12°C and food softens over time.
Insufficient Cooling / Partial Loss of Capacity
Symptom
Freezer runs constantly and never seems to shut off, even when temperature is already very cold.
Continuous Running / Poor Regulation
Symptom
Freezer temperature fluctuates widely; sometimes too warm, sometimes too cold, without changing settings.
Erratic Temperature Control
Symptom
Freezer trips the household circuit breaker or RCD when it starts.
Electrical Short or Ground Fault
Symptom
Freezer vibrates excessively or rattles against surrounding cabinets or walls.
Excessive Vibration / Poor Leveling
Symptom
Frost-free (No Frost) Hotpoint-Ariston freezer has ice buildup only on one side of the evaporator.
Partial Evaporator Frost Pattern / Sealed System Issue
Symptom
Interior light does not work when the door is opened, but the freezer cools normally.
Interior Light Circuit Failure
Symptom
Thick ice forming around the door frame or at the top of the freezer opening.
Door Gasket Air Leak / Warm Air Ingress
Symptom
Water leaking from under the freezer onto the floor.
Defrost Drain Blockage / Water Management Issue
Symptom
Water or ice pooling on the bottom of the freezer compartment.
Internal Drainage Failure
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| A1 |
Freezer display shows error A1 and the temperature is too high; food feels soft or partially thawed.
|
High Temperature Alarm / Prolonged Door Open Detection | View Details |
| A2 |
Freezer shows error A2 and the temperature is too low or fluctuating; some items may be over-frozen or frost-covered.
|
Temperature Sensor / Thermistor Fault | View Details |
| A3 |
Error A3 on display; freezer struggles to maintain temperature and may run continuously.
|
Evaporator Defrost Sensor / Evaporator NTC Fault | View Details |
| A4 |
Freezer shows error A4; unit may not defrost properly and frost builds up on the back wall.
|
Defrost Heater Circuit Fault | View Details |
| A5 |
Error A5 displayed; freezer may not cool correctly or may cycle erratically.
|
Ambient Temperature Sensor Fault | View Details |
| A6 |
Freezer shows error A6; compressor may not start or may shut down quickly.
|
Compressor Start / Inverter Communication Fault | View Details |
| AL01 |
Alarm code AL01; continuous beeping and high temperature warning.
|
High Temperature Alarm (Prolonged) | View Details |
| AL02 |
Alarm code AL02; low temperature alarm, freezer may be much colder than setpoint.
|
Overcooling Due to Sensor or Control Fault | View Details |
| AL03 |
Alarm code AL03; door alarm sounds even when the door appears closed.
|
Door Open Detection Fault | View Details |
| F01 |
Error F01 on display; freezer is not cooling or behaves unpredictably.
|
Main Control Board Failure | View Details |
| F02 |
Error F02; interior fan may not run and cooling is poor or uneven.
|
Evaporator Fan Motor Fault | View Details |
| F03 |
Error F03; freezer temperature reading is clearly wrong (e.g., shows -18°C but food is soft).
|
Freezer Compartment Temperature Sensor Error | View Details |
| F04 |
Error F04; freezer may not defrost and frost accumulates on the evaporator cover.
|
Defrost Sensor / Thermostat Error | View Details |
| F05 |
Error F05; freezer may not cool and compressor may not run.
|
Compressor Relay / Overload Fault | View Details |
| F06 |
Error F06; display or control panel may be unresponsive or show erratic behavior.
|
User Interface / Display Board Communication Fault | View Details |
| F07 |
Error F07; freezer may not maintain set temperature and may run continuously.
|
Heater or Relay Stuck On / Off (Control Board Logic Fault) | View Details |
| F08 |
Error F08; interior light or fan may not operate correctly when door is opened or closed.
|
Door Switch / Reed Sensor Fault | View Details |
| F09 |
Error F09; freezer may not respond to temperature changes or may reset unexpectedly.
|
EEPROM / Configuration Memory Error | View Details |
| F10 |
Error F10; freezer may not cool and compressor may not be commanded on.
|
Compressor Control Circuit Error | View Details |
| F11 |
Error F11; alarm beeps and display may flash, but cooling may appear normal initially.
|
Communication Error Between Display and Main Board | View Details |
| F12 |
Error F12; freezer may not accept user inputs and may be stuck in one mode.
|
User Interface Keypad Fault | View Details |
| – |
Bad smell or foul odor coming from inside the freezer, even after removing spoiled food.
|
Persistent Odor Contamination | View Details |
| – |
Burning smell or electrical odor coming from the freezer.
|
Overheating Electrical Component | View Details |
| – |
Excessive frost or ice buildup on the back wall or around drawers in a No Frost Hotpoint-Ariston freezer.
|
Defrost System Failure / Air Leak | View Details |
| – |
Freezer displays temperature but does not respond to button presses or touch controls.
|
Control Panel Unresponsive | View Details |
| – |
Freezer door will not close properly or pops open after being shut.
|
Door Alignment / Seal Failure | View Details |
| – |
Freezer interior light stays on even when the door is closed, causing warming and condensation.
|
Door Switch Stuck Open / Misalignment | View Details |
| – |
Freezer interior light works but compressor and fan do not start; no humming or clicking sounds.
|
No Start Condition (Control or Power Circuit) | View Details |
| – |
Freezer is too cold; ice cream is rock hard and items show freezer burn even at moderate settings.
|
Overcooling / Thermostat or Sensor Misregulation | View Details |
| – |
Freezer makes loud humming, buzzing, or clicking noises from the back.
|
Compressor or Condenser Fan Noise | View Details |
| – |
Freezer makes loud knocking or banging noises, especially when the compressor starts or stops.
|
Refrigerant Line or Compressor Mount Vibration | View Details |
| – |
Freezer not cooling at all; interior is at room temperature, light may work but there is no cold air.
|
Complete Loss of Cooling | View Details |
| – |
Freezer produces a high-pitched whine or squeal from inside the cabinet.
|
Evaporator Fan Motor Noise | View Details |
| – |
Freezer runs but does not get cold enough; temperature stays above -12°C and food softens over time.
|
Insufficient Cooling / Partial Loss of Capacity | View Details |
| – |
Freezer runs constantly and never seems to shut off, even when temperature is already very cold.
|
Continuous Running / Poor Regulation | View Details |
| – |
Freezer temperature fluctuates widely; sometimes too warm, sometimes too cold, without changing settings.
|
Erratic Temperature Control | View Details |
| – |
Freezer trips the household circuit breaker or RCD when it starts.
|
Electrical Short or Ground Fault | View Details |
| – |
Freezer vibrates excessively or rattles against surrounding cabinets or walls.
|
Excessive Vibration / Poor Leveling | View Details |
| – |
Frost-free (No Frost) Hotpoint-Ariston freezer has ice buildup only on one side of the evaporator.
|
Partial Evaporator Frost Pattern / Sealed System Issue | View Details |
| – |
Interior light does not work when the door is opened, but the freezer cools normally.
|
Interior Light Circuit Failure | View Details |
| – |
Thick ice forming around the door frame or at the top of the freezer opening.
|
Door Gasket Air Leak / Warm Air Ingress | View Details |
| – |
Water leaking from under the freezer onto the floor.
|
Defrost Drain Blockage / Water Management Issue | View Details |
| – |
Water or ice pooling on the bottom of the freezer compartment.
|
Internal Drainage Failure | View Details |
No matching codes found
Advertisements