Hotpoint-Ariston Continuous Running / Poor Regulation

Freezer runs constantly and never seems to shut off, even when temperature is already very cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Leaking door gasket, Thermostat or sensor out of calibration, Dirty condenser reducing efficiency, Ambient temperature too high or low

How to Fix / Troubleshooting

Safety first: Unplug the unit before cleaning coils or adjusting components.

  • Check door seal and alignment: Inspect the gasket and ensure the door closes fully. Adjust leveling so the door self-closes.
  • Clean condenser: Remove dust from condenser coils or rear grid to improve heat rejection.
  • Verify ambient conditions: Ensure the freezer is in a room within the manufacturer's recommended temperature range (typically 10–32°C). Very cold garages can cause long run times.
  • Check temperature sensor/thermostat: If the interior is already at or below the setpoint but the compressor keeps running, the sensor or thermostat may be faulty and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Gasket
Check Price on Amazon

We may earn a commission from links on this page.