AL
Igloo General Alarm Condition (Door or Temperature)

Display flashes AL and an alarm sounds; temperature may be high or door may be open.

Advertisements

Possible Causes

Door left open too long, Faulty door switch, High temperature condition, Control misreading sensor

How to Fix / Troubleshooting

Safety: No internal electrical work is required for basic checks.

Immediate actions:

  • Close the freezer door firmly and ensure nothing is blocking it from sealing.
  • Press the alarm reset or mute button to silence the alarm while you troubleshoot.

Check door switch:

  • Open the door and locate the door switch (usually near the frame). Press it manually; the interior light should turn off.
  • If the light stays on or the alarm does not reset when the switch is pressed, the switch may be faulty.
  • Unplug the freezer, remove the switch, and test for continuity with a multimeter. Replace with an Igloo-compatible door switch if defective.

Check temperature:

  • Use a separate freezer thermometer to verify actual temperature. If the freezer is warm, follow the high temperature troubleshooting steps (see H1).

Monitor: After correcting door or temperature issues, the AL alarm should clear automatically within a few hours.