Igloo High Cabinet Surface Temperature

Freezer exterior sides or top feel very hot to the touch during operation.

Advertisements

Possible Causes

Condenser coils embedded in cabinet working hard, Dirty external condenser (if present), Poor ventilation around unit, Continuous run due to gasket leak

How to Fix / Troubleshooting

Safety: Surfaces may be hot but should not be scalding. Unplug the unit before cleaning coils.

Ventilation:

  • Ensure several inches of clearance around the freezer for air circulation.
  • Do not block front or rear ventilation grilles.

Condenser cleaning:

  • If your Igloo model has exposed condenser coils, clean them thoroughly.

Door seal and run time:

  • Check the door gasket and correct any leaks to reduce compressor run time and cabinet heating.

Monitor: Some warmth is normal, especially along the door frame, but if surfaces are extremely hot or there is a burning smell, unplug the unit and have it inspected by a technician.

Advertisements

Repair Difficulty

Very Easy 1/5
Advertisements