E8
Ignis
Control Panel / Keypad Error
Display shows E8; freezer may not respond to temperature adjustments or may lock in one mode.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or shorted keypad, Moisture in control panel, Damaged ribbon cable, Faulty user interface PCB
How to Fix / Troubleshooting
Safety first: Disconnect power before opening the control panel.
- Dry the panel: If condensation or spills occurred, remove the panel and gently dry it. Allow several hours before reassembly.
- Inspect keypad: Look for stuck buttons or physical damage. Clean around buttons with a soft brush.
- Check ribbon cable: Ensure the cable between the keypad and main board is not cracked or corroded. Reseat both ends.
- Replace UI board: If E8 remains and buttons misbehave, replace the user interface / keypad board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface / Keypad Board