Possible Causes

Mis-calibrated temperature sensor, Faulty display PCB, Loose sensor connection to display, Main control board communication error

How to Fix / Troubleshooting

Safety first: Disconnect power before removing display components.

Steps:

  • Compare the displayed temperature with an accurate freezer thermometer placed inside for several hours.
  • Inspect the cabinet temperature sensor wiring and connector at the control board; reseat if loose.
  • Remove the display panel and check the ribbon cable between the display PCB and main control board.
  • If the display shows erratic values despite correct sensor readings, replace the display PCB.
  • If replacing the display does not help, the main control board may be at fault.