Proline False Alarm Due to Door Switch or Sensor Error

Alarm beeps intermittently even though the temperature appears normal and the door is closed.

Advertisements

Possible Causes

Sticky or misaligned door switch, Intermittent cabinet sensor connection, Control PCB alarm circuit fault, Door not fully closing due to obstruction

How to Fix / Troubleshooting

Steps to stop false alarms:

  • 1. Confirm door closure: Check that nothing is obstructing the door and that the gasket is sealing all around.
  • 2. Test door switch: Press the switch repeatedly to ensure it moves freely. Replace if it sticks or fails continuity tests.
  • 3. Inspect sensor wiring: Check cabinet sensor connections at the control board for looseness.
  • 4. Reset control: Unplug the freezer for 5–10 minutes to reset the alarm logic.

Note: If alarms persist despite correct operation, the main control PCB may be faulty.