E6
Proline Compressor Start / Inverter Communication Fault

Proline freezer shows E6 and the compressor may not start or may run erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty compressor start relay or PTC, Defective inverter module (on inverter-driven models), Loose harness between main PCB and compressor module, Internal compressor electrical fault

How to Fix / Troubleshooting

Safety first: Unplug the freezer. Work carefully around the compressor and high-voltage components. Do not attempt sealed-system work unless qualified.

Steps to address E6:

  • 1. Listen for compressor behavior: After plugging in (for testing only), note if the compressor clicks repeatedly, hums then stops, or does not attempt to start. Then unplug again before opening panels.
  • 2. Access compressor compartment: Remove the rear lower service panel to expose the compressor, start device, and control module.
  • 3. Inspect start relay/PTC: On non-inverter Proline freezers, the start relay/PTC is plugged onto the compressor terminals. Check for burn marks, rattling pieces inside, or melted plastic. Replace if damaged.
  • 4. Check wiring and connectors: Ensure the harness from the main control PCB to the compressor or inverter module is fully seated and not damaged.
  • 5. Test compressor windings (advanced): With the start device removed and power disconnected, measure resistance between compressor terminals (C-R, C-S, R-S). Values should be finite and consistent with a healthy compressor. A short to ground or open winding indicates a failed compressor.
  • 6. Replace faulty start device or inverter: If the compressor tests good but the start relay/PTC or inverter module is suspect, install a compatible Proline part.

Important: If the compressor windings are faulty or E6 persists after replacing the start device/inverter, a sealed-system repair or compressor replacement is required and should be performed by a licensed refrigeration technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay / Inverter Module
Check Price on Amazon

We may earn a commission from links on this page.