Proline freezer displays E9 and may not cool; compressor does not run even though lights and display are on.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Disconnect the freezer from mains before accessing the control board.
Steps to address E9:
- 1. Power reset: Unplug the unit for 10–15 minutes, then reconnect. If E9 returns immediately, proceed with inspection.
- 2. Access main control PCB: On many Proline freezers, the main board is located in a rear control box or behind the top control fascia. Remove the cover carefully.
- 3. Visual inspection: Look for burned components, swollen capacitors, or cracked solder joints, especially around the compressor relay.
- 4. Check connectors: Ensure all harnesses are fully seated and not heat-damaged.
- 5. Basic relay test (advanced): With power applied and a cooling demand present, listen/feel for the compressor relay clicking. If there is no click and the board shows visible damage, replacement is likely required.
- 6. Replace main control PCB: Order the correct Proline main control board by model number. Transfer any jumper settings or wiring exactly as original. Label connectors before removal to avoid miswiring.
Note: Board-level repair is not recommended for most users. If you are not experienced with electronics, have a technician replace the PCB.
Repair Difficulty
Required Part
We may earn a commission from links on this page.