Proline Thermostat / Temperature Control Miscalibration

Freezer interior is too warm; compressor cycles on and off but temperature remains above -10°C.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty mechanical thermostat (on basic Proline chest freezers), Misreading cabinet NTC sensor, Loose sensor from cabinet wall, Control PCB calibration error

How to Fix / Troubleshooting

Safety first: Unplug the freezer before accessing the thermostat or control housing.

Steps to check temperature control:

  • 1. Verify with a thermometer: Place an accurate freezer thermometer inside and compare actual temperature to the setpoint.
  • 2. Adjust setting: Turn the thermostat or digital setting to a colder position and monitor for several hours. If there is no change, the control may be faulty.
  • 3. Mechanical thermostat models: Access the thermostat knob area, remove the cover, and inspect the capillary sensor bulb. Ensure it is properly positioned against the evaporator plate or wall. Replace the thermostat if it does not switch the compressor on/off correctly.
  • 4. Electronic models: Test the cabinet NTC sensor and replace if out of specification. If sensor is good, the main control PCB may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Thermostat / Temperature Control
Check Price on Amazon